Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
Related parameters
Param
Code
Name
Note:
Notch filter 1
P08-30
frequency
Setting range: 300-5000, unit: Hz
Center frequency of trap 1
When set to 5000, the trap is not valid
Notch filter 1
P08-31
width
Setting range:50-1000
Notch width class for Notch 1
is the ratio of the width to the center frequency
Setting range:0-1000
Notch filter 1
P08-32
Depth
Notch depth level for Notch 1
The ratio between the input and the output is given for the center frequency of
the trap
The larger this parameter, the smaller the notch depth and the weaker the effect
Relevant parameters of notch filter
Param
Code
Name
P08-24.0 First trap enable
P08-24.1 Second trap enable
P08-30 Notch Filter 1 Frequency
P08-31 Notch Filter 1 Width
setting range
leave
the
factory
setting
Unit of
Measure
0-1
0
---
0-1
0
---
50-5000
5000 HZ
50-1000
70
0.01
Entry
into
force
Time
Effective
immediate
ly
Effective
immediate
ly
Effective
immediate
ly
Effective
immediate
75
    "