Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
The starting position is at theCCW direction side of HS limit: the motor firstly moves in
CW direction at the speed of P03-65 returning to the mechanical origin. When HS limit is activated
effectively, it will decelerate and stop according to the deceleration of P03-67, and then move
in CCW direction in reverse direction. When it leaves HS limit, the first Z signal is the zero
origin;
The starting position is onHS limit: the motor runs at low speed in CCW direction according
to P03-66
, when leaving the HS limit, the first Z signal is the return to zero origin;
The starting position is at the CW direction side of HS limit: the motor first moves in CW
direction at the speed of P03-65 returning to the mechanical origin. When it encounters the CW
limit, it will reverse to CCW direction. After it encounters the HS limit, it will continue to
run in CCW direction. When leaving the HS limit, the first Z signal is the return to zero origin.
Figure III Schematic diagram of three tracks of zero return mode
Return to zero mode 4
WhenP03-61 = 4, select return to zero mode IV:
Take the CCW direction end of HS limit as reference point, and the first Z signal in CW
direction as zero point.
The starting position is at the side of HS limit CCW direction: the motor first moves in
CW direction at the speed of P03-65 returning to the mechanical origin. When the HS limit is
effectively activated, the motor decelerates according to the deceleration of P03-67, and it returns
to the zero origin when it meets the first Z signal.
186