Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
Figure 26 Schematic diagram of 28 tracks of return to zero mode
Return to zero mode29
WhenP03-61 = 29, select return to zero mode 29:
Take the CCW direction end of HS limit as zero point.
The starting position is at theside of HS limit in CCW direction: the motor firstly moves
in CCW direction at the speed of P03-65 returning to the mechanical origin; after the CCW limit
is activated, the motor moves in CW direction in reverse direction; when the HS limit is activated,
the motor stops; this point is the zero return origin;
Starting position is onHS limit: run in CCW direction at low speed, run in CW direction in
reverse direction after leaving HS limit according to P03-66 to set low speed, and stop when HS
limit is activated again, this point is the zero return origin;
The starting position is atthe CW direction side of HS limit: the motor first moves in CCW
direction at the speed of P03-65 returning to the mechanical origin, and after activating and then
leaving HS limit, it decelerates to move in CW direction, and stops when HS limit is activated.
This point is the zero return origin;
208