Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
Fig.14 Schematic Diagram of Fourteenth Track of Return to Zero Mode
Return to zero mode15/16
The return to zero mode is reserved. When the return to zero mode is selected, there is no
action.
Return to zero mode17
WhenP03-61 = 17, select return to zero mode 17:
The CW direction end limited in CCW direction is the zero point.
The starting position is on theCCW limit: the motor runs at low speed in CW direction according
to P03-66, and stops when it leaves the CCW limit, which is the zero return origin;
The starting position is atthe CW direction side of CCW limit: the motor first moves at the
speed of P03-65 to return to the mechanical origin in the CCW direction, after the re-CCW limit
is activated, the motor runs at a low speed in the CW direction according to the setting of P03-66,
and stops when it leaves the CCW limit, which is the zero return origin;
Fig.15 Schematic diagram of seventeen tracks in return to zero mode
197