Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
performance
input/output
humidity
altitude
Work: 10% to 90%
<1000m, above 1000 m, should be used in accordance with
GB/T 3859.2-93 derating
protection class
Speed adjustment
range
Protection class: IP10
Cleanliness: 2
No corrosive gas, flammable gas, no oil, water splash,
dust, salt and less metal powder environment
1:6000
±0.01%: external load variation 0~100%
steady speed accuracy
±0.01%: ±10% power input variation at 220V
±0.1%: Ambient ±25(25)
speed response
frequency
Torque control
accuracy
2000Hz
±2%
Encoder frequency
division pulse
output
(P28 Series without
this output)
Phase A, Phase B differential output
Z-phase differential output or open-collector output
Frequency division pulse number: can be set arbitrarily
P28
input signal
P28
Number of points: 5
Functions: servo ON, alarm clearing, forward overtravel signal
input, reverse overtravel signal input, control mode switching, P
action command input, forward rotation side external torque
limit, reverse rotation side external torque limit, gain switching
input, zero position fixing input, command pulse prohibition
input, encoder absolute value data request input, internal set
speed switching input 1, internal set speed switching input 2,
internal set speed switching input 3, position command clearing
input, etc.
Number of points: 4
14
    "