Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
Fault alarm reason
Wrong selection of regenerative
resistor or no external
regenerative resistor
Parameter setting error
Fault alarm check
Check the connection of the
regenerative resistor
Please confirm theparameter setting
ofP00-30~P00-34
disposal measures
If the connection is normal, return
the drive to the factory for repair
P00- 44.2 canbe set to 0 to turn off
the alarm
Set parameter values correctly
E.431: Regeneration Overload
Fault alarm reason
Wrong selection of regenerative
resistor or no external
regenerative resistor
Incorrect parameter setting
Fault alarm check
Check the connection condition of
the regenerative resistor and
whether the resistance and power of
the regenerative resistor are suitable
Confirm whether the parameters
P00-30~P00-35 are correct
disposal measures
Select the appropriate regenerative
resistor
Set parameter values correctly
E.435: Surge current limiting resistor overload
Fault alarm reason
Frequent power-up of drive power
supply
Fault alarm check
disposal measures
P00-44 can be set to turn off the
alarm
E.436: DB Overload
Fault alarm reason
Motor driven by external force
(rdy state)
DB, the rotational energy is
greater than the DB resistance
capacity
Fault alarm check
Confirm running status
Check motor running speed
Evaluate whether the load inertia is
too large
disposal measures
Do not use excessive external force
to push
P00- 46 can be set to turn off the
alarm
Reduce servo motor command
speed
Reduce the load moment of inertia
Reduce the number of DB stops
E.440: Radiator Overheated
Fault alarm reason
Drive internal temperature above
P00-41 setpoint
Fault alarm check
Check that the drive is in good
thermal condition
disposal measures
Improve the heat dissipation
condition of the drive. If the alarm
162