Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
P00-46
P00-47
P00-50
P00-51
P00-52
Soft start resistor
3 overload fault setting
(E.435)
Setting range: 0-1
0: Close fault
1: Fault allowed
DB overload fault
0
setting (E.436)
Motor runaway
1 detection fault setting
(E.421)
Setting range: 0-1
0: Close fault
1: Fault allowed
Setting range: 0-1
0: Close fault
1: Fault allowed
Abnormal u-phase
2 current feedback
(E.071)
Setting range: 0-1
0: Close fault
1: Fault allowed
Abnormal w-phase
3 current feedback
(E.072)
Setting range: 0-1
0: Close fault
1: Fault allowed
Motor power line off
0 line fault setting
(E.305)
Setting range: 0-1
0: Close fault
1: Fault allowed
FPGA clock
Setting range: 0-1
1 exception fault setting 0: Close fault
(E.069)
1: Fault allowed
Motor locked-rotor
protection time
Setting range: 0-60000Unit: ms
Set the time to trigger the AL410 alarm protection formotor locked-rotor
overload warning
value
Undervoltage alarm
voltage value
Setting range: 0-100Unit: %
Set the overload warning threshold as a percentage of the overload
warning time. When 60% is set, overload alarm is triggered when
overload accumulation reaches 60% of overload alarm.
Setting range: 0-500 units: V
Setundervoltage alarm threshold
116