A.971: Undervoltage warning
Fault alarm reason
The input voltage of the main
circuit is lower than the rated
voltage value or there is no input
voltage
I/O port are correct
Fault alarm check
Check whether the main circuit
input L1,L2,L3 wiring is correct,
and the voltage value is how many
volts. The bus voltage can be
monitored via d23.dcp
disposal measures
Make sure that the wiring is correct
and that the correct voltage source
or voltage regulator is used in
series
P00-52 Alarm threshold can be
modified or alarm can be turned off
Chapter X Communication
10.1 Modbus communication parameter setting
paramete
r code
Name
P00-23 slave address
P00-24.0 Modbus
Description
Setting range: 0-255, default 1
Set according to equipment requirements
Setting range: 0-7, default 2
169