Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
communication baud
rate
P00-24.1 check mode
P00-26
Modbus
communication
response delay
0:2400
1:4800
2:9600
3:19200
4:38400
5:57600
6:115200
7:25600
Setting range: 0-3, default 0
0: no check, 2 stop bits
1: even parity, 1 stop bit
2: Odd parity, 1 stop bit
3: No check, 1 stop bit
Setting range: 0-100, default 0
When the parameter is set to 0, the response is made according to the
standard communication. When the parameter is set to have a value, the
response time of Modbus communication is made according to the set
time
10.2 Modbus communication supports reading and writing parameter
setting
Support reading monitoring project address list
monitorin
Definition
Unit of
Decimal communication address
g item
Measure
(double address, high order first)
d00.C.PU
position command pulse instruction
2100-2101
sum
unit
170