Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
2
01
P06-23
2
01
P06-24
2
P06-40
P06-41
P06-42
P06-43
P06-46
Settings-Function
Selection
DO2 terminal
setting-logic selection
DO3 Terminal
Setup-Function Selection
DO3 terminal
setting-logic selection
DO4 Terminal
Settings-Function
Selection
DO4 terminal
setting-logic selection
Speed value
corresponding to speed
analog quantity 1V
AI1 filter time constant
AI1 Bias
Torque value
corresponding to torque
analog quantity 1V
AI1 analog deadband
See P06-21.2
See P06-21.01
See P06-21.2
See P06-21.01
See P06-21.2
Setting range: 10-2000, unit:1rpm/V
Sets the coefficient between the analog command and the speed
control command input by CN1
Example: 500 represents 500 revolutions per minute per V
Setting range:0-2500, unit: 0.01ms
Sets the analog command filter time factor for the AI1 input
Setting range: -9999-9999, unitV
Sets the analog command zero offset for the AI1 input
Setting range: 0-100, unit: 1%
Sets the coefficient between the analog command and the speed
control command input by AI1
For example: 30 represents 30% of rated torque per V
Setting range: 0-9999 unit:mv
Set the dead zone voltage value of speed analog command. When
the analog quantity is set within the positive and negative value
range, the system defaults to zero
141