Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
Fig.19 Schematic diagram of 21 tracks of return to zero mode
Return to zero mode22
WhenP03-61 = 22, select return to zero mode 22:
Take the CW direction end of HS limit as zero point.
The starting position is at theCCW direction side of HS limit: the motor first moves in CCW
direction at the speed of P03-65 returning to the mechanical origin. When the CCW limit is activated,
the motor will run in CW direction in reverse. After the HS limit is activated, the motor will
decelerate and run at low speed according to the setting of P03-66. After leaving the HS limit,
the motor will run in CCW direction in reverse. When the HS limit is activated, the motor will
stop. This point is the zero return origin.
The starting position is on theHS limit: the motor runs at a low speed in the CW direction
according to P03-66. After leaving the HS limit, it runs in the CCW direction in the reverse direction.
When the HS limit is activated, it stops. This point is the zero return origin;
The starting position is atthe CW direction side of HS limit: the motor first moves in CCW
direction at the speed of P03-65 returning to the mechanical origin, and stops when HS limit is
activated, which is the zero return origin;
201