Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
P05-14
~
P05-17
Internal setting torque 1 to
4
terminal logic
torque limiting value
effective
External clipping
value P05-13
invalid
Internal clipping
value P05-11
If the DI function is not assigned, the system defaults to P05-11 for
torque clipping
When the torque output reaches the limit value,the torque limit
signal can be output through the DO port
Setting range: -300-300, unit:% rated torque
Parameters P05-14 to P05-17 set internal torque 1 to internal torque 4,
respectively
The internal speed switching method is as follows:
P05-00 is set to 3 when the torque loop is controlled.
The corresponding input port functions are defined as11, 12
Example: Use input signal ports DI3, DI4. I/O port functions are
defined as 11 and 12 respectively (see P06- 11 parameter description
for function definition), and torque switching operation corresponding
to parameter setting is realized through I/O level combination.
DI3
DI4 action
parameter
0
0
P05-14
1
0
P05-15
0
1
P04-16
1
1
P04-17
8.2.7 P06-xx I/O Parameters
parameter
code
P06-00
Name
Power-up active DI
Note:
Setting range: 00-ffff Factory setting: 0