Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
d18.AnG
d19.HAL
d20.ASS
d21.ASH
d22.J-L
d23.dcp
d24.Ath
Motor mechanical angle
electrical angle
Absolute encoder single
turn value
Absolute encoder
multiturn value
inertia ratio
Main circuit voltage
(DC value)
Drive Temperature
relationship with the output port is that the four
vertical bars from right to left of the operation panel
respectively correspond to DO1-DO4
This parameter can monitor the mechanical angle of
the motor. One rotation is 360 degrees
Phase sequence position of incremental encoder
motor
Electrical angle of absolute encoder
This parameter can monitor the feedback value of
the absolute encoder, and the value changes from 0
to8388607after one rotation
This parameter monitors the number of revolutions
of the multi-turn absolute encoder motor
This parameter can monitor the real-time inertia of
the load carried by the motor
This parameter can monitor the DC voltage value of
the main circuit
This parameter monitors the drive temperature
d25.tiE
d26.1.Fr
d28.2.Fr
d29.cn
d30.Ai1
d31.Ai2
d32.c.Er
cumulative running time
Resonance frequency 1
Resonance frequency 2
Current Control Mode
Input voltage of Ai1
port
Input voltage of Ai2
port
Number of abnormal
communication of
encoder
This parameter monitors the drive run time in:
second
This parameter monitors the resonance frequency 1,
the high frequency resonance frequency
This parameter monitors the resonant frequency 2,
the low frequency resonant frequency
This parameter can monitor the current control
mode. Refer to parameter P01-01 for specific
corresponding relationship
This parameter monitors the Ai1 input voltage value
This parameter monitors the Ai2 input voltage value
(not available for P28 series)
This parameter can monitor the number of abnormal
communication of encoder after power-on
0.1 degree
0.1 degree
decimal
system
decimal
system
%
V
degree
centigrade
second
Hz
Hz
0. 001V
0.001V
148