Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
A.905
A.910
A.911
A.912
A.913
A.920
A.921
A.923
A.930
A.941
A.942
A.950
A.960
A.971
A.995
Auxiliary (F**) function cannot be executed when servo is ON
overload
vibration
Abnormal temperature of control board
Drive Temperature Abnormal
regenerative overload
DB overload
Servo unit internal fan stops
Encoder Battery Low Voltage
Parameter changes that require power reconnection
EEPROM write failure
overtravel
Input terminal duplicate definition
undervoltage
Advanced accessibility dysfunction
9.2 Fault alarm cause and treatment
E.051: EEPROM Parameter Abnormal
Fault alarm reason
Servo unit EEPROM data
exception
Fault alarm check
Perform factory initialization
(F10.INI)
E.052: FPGA Communication Exception
Fault alarm reason
Abnormal power-on initialization
of main control MCU
Fault alarm check
Power back on
E.053: Initialization Failure
Fault alarm reason
Power-on initialization failure of
Fault alarm check
Power back on
disposal measures
If it persists, replace the drive
disposal measures
Alarm is switched off by setting
parameter Pn044
If it persists, replace the drive
disposal measures
If it persists, replace the drive