F11.Err
F12.clr
F13.unL
F14. out
Fault log shows
Alarm record
clearing
Operation
authority setting
Force output port
level
press theENT key to enter
2. Select the parameter range to be restored: input the corresponding code
according to the following table, and select the parameter range to be
restored. Press and hold theENT keyuntil a progress bar appears untilfinsh
flashes, completing the factory reset.
Code
implication
51
Restore Level 1 Privilege Parameters (Application
Parameters)
52
Restore level 2 privilege parameters (application
parameters + motor parameters)
55
Restore all parameters (including hidden parameters)
1. Press theM keyon the operation panel to switch to the auxiliary
modeF**, operate theUp/Down key toF11.Err, and press theENT key to
display the past 8 times of historical fault information. The number on the
left is F 0, which represents the most recent failure
2. Press the Up keyto display past faults one by one. PressENT key for
along timeto display the fault occurrence time. Refer to d25.tiE for time
coordinate.
3. Press theM key to exit the mode.
Note:The fault occurred during multiple power-up and power-down within
30 minutes may have a 30-minute deviation in its recording time.
1. Press theM keyof the operation panel to switch to the auxiliary
modeF**, operate theUp/Down key toF12.clr, press theENT key, the
panel displaysclr.Er, and press theENT key to clear the alarm information
recorded inF11.Err.
2. Press theM key to exit the mode.
1. Press theM keyof the operation panel to switch to the auxiliary
modeF**, operate theUp/Down key toF13.unL, and press theENT key to
edit the operation authority. 0: Parameters cannot be modified;1:
Parameters can be modified (except system parameters); 2: All visible
parameters can be modified; Set the value of 0,1, and save when power is
off. When setting 2, it will not be saved after power failure.
2. Press theM key to exit the mode.
1. Press the M key of the operation panel to switch to the auxiliary mode
F**, and operate the Up/Down key to F14. out, press ENT key to force
output port level through Up/Down key. The corresponding relation with
the output port is that the four vertical bars of the operation panel from right