filter Q value
0 First trap selection
1 Second trap selection
Friction
3 compensation
function selection
Setting range:0-1
0: the first trap is not active,
1: first trap active
Setting range:0-1
0: 2nd trap invalid
1: second trap active
Setting range:0-1
0: Invalid
1: Effective
Adaptive Notch 1
0
Mode Settings
Setting range:0-1
0: Invalid
1: Allow the drive to automatically set the first trap
Adaptive Notch 2
1
Mode Settings
Setting range:0-1
0: Invalid
1: Allows the drive to automatically set the second trap
Notch Filter 1
Frequency
Notch Filter 1 Width
Notch Filter 1 Depth
Notch Filter 2
Frequency
Setting range: 300-5000, unit: Hz
Center frequency of trap 1. P 08 -24.0 needs to be set to enable
to be effective
When set to 5000, the trap is not valid
Setting range: 50-1000 Unit: 0.01
Notch width class for Notch 1
is the ratio of the width to the center frequency
Setting range:0-99
Notch depth level for Notch 1
The ratio between the input and the output is given for the center
frequency of the trap
The larger this parameter, the smaller the notch depth and the weaker
the effect
Same as P08-30. P08-24.1 needs to be set to enable to be effective