Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
P00-34
P00-35
P00-39
P00-40
P00-41
P00-42
P00-43
P00-44
Resistance of built-in
braking resistor
heat dissipation
coefficient of
resistance
Three-phase power
0
input selection
Electrical signal
1
shielding on RST
Temperature
Compensation
Settings
Overtemperature
alarm setting
Overtemperature
warning setting
Fan startup
temperature setting
0 Fan Fault Settings
Communication with
1 FPGA abnormal fault
setting (E.052)
Setting range: 1-65535, unit: 0.1 ohm
Set correctly according to the value of the built-in braking resistor
Setting range: 1-100, unit: %
Set reasonably according to the heat dissipation conditions of the resistor.
If the heat dissipation conditions are good, the value can be set
appropriately. When the setting value is large, the allowable energy of
resistor regeneration increases, and it is not easy to report regeneration
overload.
Setting range: 0-1
0: Single power input
1: Three-phase power input (phase loss alarm AL400 will be generated
when phase loss occurs)
Setting range: 0-1
0: power-on judgment signal for normal use
1: shield power-on signal
Setting range: -20-20, unit: degree centigrade
Correction of deviation of d24.Ath from actual temperature by parameter
value
Setting range: 1-150, unit: degree centigrade
Alarm when radiator temperature reaches set value E.440
Setting range: 1-150, unit: degree centigrade
Overtemperature warning when radiator temperature reaches set value
Setting range: 1-150, unit: degree centigrade
The fan starts when the radiator temperature reaches the set value
Setting range: 0-1
0: Close fault
1: Fault allowed
Setting range: 0-1
0: Close fault
1: Fault allowed
Regeneration
2 abnormal alarm
(E.430)
Setting range: 0-1
0: Close fault
1: Fault allowed
115