square after activating HS limit. When leaving HS limit, the first Z signal is the zero origin;
Figure 5 Schematic diagram of five tracks of return to zero mode
Return to zero mode6
WhenP03-61 = 6, select return to zero mode VI:
Take the CW direction end of HS limit as reference point, and the first Z signal in CCW
direction as zero point.
The starting position is at theside of HS limit in CCW direction: the motor first moves in CW
direction at the speed of P03-65 returning to the mechanical origin, and when it encounters the
limit in CCW direction, it will reverse to CW direction. When HS limit is activated, it will
decelerate. After leaving HS limit, it will run at low speed in CCW direction according to P03-66.
When HS limit is activated, the first Z signal is the zero origin;
The starting position is onHS limit: the motor runs at low speed in CW direction according
to P03-66. After leaving HS limit, the motor runs at low speed in CCW direction. After activating
HS limit, the first Z signal is the zero origin;
The starting position is atthe CW direction side of HS limit: the motor first moves in CCW
direction at the speed of P03-65 returning to the mechanical origin, and after activating HS limit,
the first Z signal is returning to the zero origin;