Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
P03-03
P03-04
P03-05
P03-06
P03-07
P03-09
P03-15
P03-17
deviation
instruction pulse
0
negation
instruction pulse active
1
level negation
instruction pulse filter
Positioning completion
output condition
Positioning completion
range
Positioning proximity
threshold
Number of command
pulses for one rotation
of motor
Excessive position
deviation setting
position command
Used to adjust the pulse instruction counting direction
0: Normal.
1: Direction reversed
0: rising edge count
1: falling edge count
Setting range:0-2000 Unit: 0.1us
Instruction pulse filter width setting, filter width = set value *0.1(us)
0: Position deviation is less than P03-06 set value
1: The position deviation is less than the set value of P03-06, and the
filtered position command is 0.
2: Position deviation is less than P03-06 set value, and the command
after position command is 0
Setting range: 0-65535 units: instruction unit
It is used to set the threshold value of the output signal of positioning
completion, and the set value is the command unit (refer to
parameters P03-09, P03-40 and P03-42).
The positioning completion range is used as the judgment basis of
position gain setting in the one-key self-setting function.
Setting range: 0-65535 units: instruction unit
It is used to set the threshold value of positioning approach output
signal, and the set value is the command unit (refer to parameters
P03-09, P03-40 and P03-42).
Setting range: 0-1073741823
Used to set the number of command pulses for one rotation
of the motor. When this parameter is set to 0, P03-40 and
P03-42 parameters are valid.
Setting range: 0-1073741823 Unit: Command Unit
Set the pulse number of allowable deviation, and alarm E.501 when
exceeding the set value; Not detected when set to 0
Setting range: 0-10000 Unit: 0.1ms
130