Fig.12 Schematic diagram of twelve tracks in return to zero mode
Return to zero mode13
WhenP03-61 = 13, select return to zero mode 13:
Take the CCW direction end of HS limit as reference point, and the first Z signal in CW
direction as zero point.
The starting position is at theCCW direction side of HS limit: the motor moves in CCW direction
at the speed of P03-65 to return to the mechanical origin. After the CCW limit is activated, the
motor decelerates to move in CW direction. After the HS limit is activated, the first Z signal
is the zero origin;
The starting position is onHS limit: the motor runs at low speed in CCW direction according
to P03-66. After leaving HS limit, the motor runs at low speed in CW direction. After activating
HS limit, the first Z signal is the zero return origin;
The starting position is atthe CW direction side of HS limit: the motor first moves in CCW
direction at the speed of P03-65 returning to the mechanical origin, and then moves in CW direction
at low speed after activating and leaving HS limit. After activating HS limit, the first Z signal
is the zero origin;