Overheat alarm threshold setting
is too small
Check parameter P00- 41
still occurs, please return the drive
to the factory for maintenance.
Set P00- 41
E.501: Excessive positional deviation
Fault alarm reason
Too large position deviation, too
small setting parameter
Gain value set too small
Internal torque limit set too small
Fault alarm check
Confirm parameter setting of P0
3-15 (excessive position deviation
setting)
Confirm whether the gain
parameters are set reasonably
Confirm internal torque limit value
Excessive external load
Check external load
disposal measures
Increase the setting of P0 3-15
(excessive position deviation
setting)
Readjust the gain class parameters
correctly
Readjust the internal torque limit
correctly
Reduce the load or replace the
high-power motor
E.503: Excessive position deviation when servo is ON
Fault alarm reason
Excessive position deviation when
servo is ON
Gain value set too small
Internal torque limit set too small
Fault alarm check
Confirmparameter settingof P03-30,
P03-31 and P0 3-3 3
Confirm whether the gain
parameters are set reasonably
Confirm internal torque limit value
Excessive external load
Check external load
disposal measures
Correctly set relevant parameters
Readjust the gain class parameters
correctly
Readjust the internal torque limit
correctly
Reduce the load or replace the
high-power motor
E.510: Excessive gantry position deviation
Fault alarm reason
The gantry position deviation is
too large
Gain value set too small
Internal torque limit set too small
Fault alarm check
Confirm P03-53 parameter setting
Confirm whether the gain
parameters are set reasonably
Confirm internal torque limit value
disposal measures
Set parameter values correctly
Readjust the gain class parameters
correctly
Readjust the internal torque limit
correctly