Excessive external load
Check external load
Reduce the load or replace the
high-power motor
E.511: Gantry shaft alarm
Fault alarm reason
Two-axis drives, P 00-39, have an
axis associated alarm set and one
axis alarm.
Two-axis drive, open gantry
function, one of the axis alarm
Fault alarm check
Check whether each axis gives an
alarm
Check whether each axis gives an
alarm
disposal measures
Perform alarm (other alarms)
troubleshooting
Perform alarm (other alarms)
troubleshooting
E.520: Vibration Alarm
Fault alarm reason
Abnormal vibration of motor
speed detected
The value of the moment of
inertia ratio (P01-04) is larger than
the actual value or varies greatly
Fault alarm check
Confirm the abnormal sound of the
motor and the speed and torque
waveform during operation.
Confirm the load moment of inertia
ratio
disposal measures
Reduce the motor speed.
Or reduce the speed loop gain
(P02-10)
Set the appropriate ratio of moment
of inertia (P01-04)
P01-10 can be set to turn off the
alarm
E.521: Self-adjusting vibration alarm
Fault alarm reason
The motor vibrates greatly when
using the adjustment-free function
(factory setting)
Fault alarm check
Confirm the waveform of the motor
speed.
Motor vibration is high when
performing advanced auto tuning,
single parameter tuning, EasyFFT
Confirm the waveform of the motor
speed.
disposal measures
Decrease the load moment of
inertia ratio below the allowable
value, or increase the tuning value
of the adjustment free value setting
(Fn200), or decrease the gain value.
The processing method described
in the operation procedure for
implementing each function
E.620: Encoder Off Line
Fault alarm reason
Bus encoder communication
Fault alarm check
Check Encoder Wiring
disposal measures
correct wiring