Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
setting out of range
E.107: Abnormal parameters
Fault alarm reason
parameter anomaly
setting parameters. P03-25
division pulse output parameters
Bus encoder P03-25 65535
Drive Power Back On
Fault alarm check
Check whether the parameter range
is reasonable
disposal measures
Set parameters correctly
Execute parameter initialization
E.108: Parameter setting out of range
Fault alarm reason
Parameter setting out of range
Fault alarm check
Check whether the parameter range
is reasonable
disposal measures
Set parameters correctly
Execute parameter initialization
E.120: Servo ON command invalid alarm
Fault alarm reason
When servo is ON, power supply
input ports L1, L2 and L3 are not
supplied with power
Fault alarm check
Check wiring and input voltage
disposal measures
Check wiring
Drive Power Back On
E.121: External input alarm signal
Fault alarm reason
External input alarm signal
Fault alarm check
Check whether there is signal input
at the external input port and
whether the relevant parameters of
I/O port are correct
disposal measures
Correct use of external input alarm
IO signals
E.305: Broken motor cable
Fault alarm reason
Motor cable broken
Fault alarm check
Check whether the UVW wiring is
correct and the connection is
reliable
disposal measures
Ensure UVW wiring is correct and
reliable
P00-47.0 Set 0 to turn off alarm
159