Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
P05-06
Torque limit detection
signal output delay
P05-10
Forward internal torque
limit
P05-11
Reverse internal torque
limit
P05-12
Forward external torque
limit
P05-13
Reverse external torque
limit
Setting range: 0-10000, unit: ms
Set signal delay time in DO port outputtorque limit
Setting range: 0-350 units: 1% rated torque
Limit motor forward output, 100 means 1 times torque, 300
means 3 times torque
When the torque output reaches the limit value,the torque limit
signal can be output through the DO port
Setting range: -350-0 units: 1% rated torque
Limit the reverse output of the motor. Set 100 to represent
1 times torque and 300 to represent 3 times torque.
When the torque output reaches the limit value,the torque limit
signal can be output through the DO port
Setting range: 0-350 units: 1% rated torque
This function is switched using one of the external input ports in CN1,
setting the selected DI portinput port function selection to 7
(positive external torque limit value). The control mode can be
switched by controlling the logic state of the port.
terminal logic
torque limiting value
effective
External clipping
value P05-12
invalid
Internal clipping
value P05-10
If the DI function is not assigned, the system defaults to P05-10 for
torque clipping
When the torque output reaches the limit value,the torque limit
signal can be output through the DO port
Setting range: 0-350 units: 1% rated torque
This function is switched using one of the external input ports in CN1,
setting the selected DI portinput port function selection to 8
(reverse external torque limit value). The control mode can be
switched by controlling the logic state of the port.
135