P01-13
Residual vibration
detection amplitude
Setting range: 1-3000 Unit: 0.1%
Based on the positioning completion threshold
P01-20
P01-20
P01-21
P01-22
Servo OFF and
0 stop method when
Gr.1 fault occurs
Stopping method in
1
case of Gr.2 fault
Stopping method in
2
case of overtravel
Stop method when
3
forced stop
Stop torque at
emergency stop,
fault and over
travel
E-stop, fault,
Setting range: 0-2 It is necessary to confirm whether the driver
has DB hardware circuit
0: Stop the motor by DB, then hold DB.
1: Stop the motor through DB, then release DB.
2: Do not use DB, stop freely
0: Use the settings in P01- 20.nX.
1: Set the torque to decelerate and shut down according to P01-21, and then
follow the setting in P01- 20.nX after shutdown.
2: Decelerate and shut down according to P01-22 deceleration time, and
then follow the setting in P01- 20.nX
0: Use the settings in P01- 20.nX.
1: Set the torque according to P01-21 to decelerate and stop, and lock the
servo after stopping.
2: Set the torque according to P01-21 to decelerate and shut down, and
enter the free running state after shutdown.
3: Stop the machine according to the deceleration time of P01-22, and lock
the servo after the machine is stopped.
4: Decelerate and shut down according to the deceleration time of P01-22,
and enter into free running state after shutdown
0: Use the settings in P01- 20.nX.
1: Set the torque to decelerate the shutdown according to P01-21, and use
the setting in P01- 20.nX after shutdown.
2: Decelerate and stop according to P01-22 Deceleration Time, and use the
setting in P01- 20.nX after stopping.
Setting range:0-350 Unit: %
Set the deceleration stop torque in case of emergency stop, fault and
overtravel
Setting range:0-60000 Unit: ms
120