P01-03
Real-time
automatic
adjustment of
stiffness settings
P01-04
ratio of moment of
inertia
P01-05
Mute adjustment
0
selection
Quiescent Current
2
Base Gain
gain), P02-14 (speed integral constant 2), P08-20 (torque command filter
constant 1), P08-21 (torque command filter constant 2)
4: Automatic adjustment, depending on parameters P01-05, P01-06
Setting range:0-31
Built-in 32 kinds of gain parameters, when P01-02 is set to 1, 2, 3 when the
effect. Can be directly called according to the actual situation, the larger
the set value, the stronger the rigidity.
Setting range:0-20000, unit: 1%
Set the load inertia ratio of the corresponding motor as follows:
P01-04= load inertia/motor moment of inertia
For this inertia ratio, use the value after F19.J-L automatic inertia
identification, and write the identified value into the parameter
Setting range:0-1
0: Turn offmute adjustment
1: Turn onmute adjustment
Setting range:0-8
The smaller the value, the smaller the current gain at low loads. 0:
corresponds to 20%, 8 corresponds to 100%.
P01-06
P01-06
0 self-adjusting value
Self-adjusting load
1
value
Setting range:0-7
it work when P01-02 is set to 4, that higher the value, the more
rigid it is.
Setting range:0-2, when P01- 0 - 2 is set to 4, it will take effect
The larger the value, the more the model loads
P01-10
P01-11
P01-12
Vibration detection
selection
Vibration detection
sensitivity
Vibration detection
level
Setting range:0-2
0: No vibration detection (E.520 alarm off)
1: Warning after vibration detection (close A. 911 Warning
2: Alarm after vibration detection
Setting range:50-500, unit: %
Percentage based on P02-52
Setting range: 0-5000 Unit: rpm
Vibration detection level base