Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
P0 3-66
P0 3-67
P0 3-68
P0 3-69
P06-11.01
P06-13.01
P06-14.01
P06-12.01
P06-15.01
P06-21.01
deceleration point signal.
The motor is always running at high speed P03-65 when electrically
zeroed.
Speed when searching for
home switch_low speed
Setting range: 0-1000, default 10
Set the low-speed speed value when searching for the origin when the
origin returns to zero.
The speed setting should be low enough to prevent mechanical shock
during shutdown.
Search for origin switch
acceleration/deceleration
time
Set the time when the motor changes from 0 to 1000rpm at the time
of home reset. Unit:MS
Maximum time limit for
searching origin
Limit the total time of home reset, and alarm AL.551(home reset
timeout fault) will occur if the time is exceeded.
Mechanical origin offset
Setting range: -1073741823-1073741823, default:0 unit: instruction
unit
Set mechanical origin offset after origin reset
DI1 Input Port Function DI1 set to 1, servo ON
Selection
DI3 Input Port Function DI3 set to 3, positive overtravel signal input
Selection
DI4 Input Port Function DI4 set to 4, reverse overtravel signal input
Selection
DI2 Input Port Function DI2 set to 15, home switch signal
Selection
DI5 Input Port Function DI5 set to 16, start signal of home reset
Selection
DI6 Input Port Function DO1 is set to 0D, and the signal of home reset completion
Selection
183