Shenzhen Just Motion Control electromechanics co., ltd
0755-26509689
P08-06
P08-07
P08-09
P08-10
P08-11
P08-12
P08-15
Program JOG mode
Program JOG Move
Distance
Program JOG
moving speed
PROGRAMME JOG
ACCELERATION
DECELERATION
TIME
Program JOG Wait
Time
Number of program
JOG moves
Auto Adjust Settings
0
0
Setting range: 0-5
0:(waiting time P08-11-> forward movement P08-07)* number of
movements P08-12
1:(waiting time P08-11-> reverse movement P08-07)* number of
movements P08-12
2:(waiting time P08-11-> forward movement P08-07)* number of
movements P08-12->(waiting time P08-11-> reverse movement
P08-07)* number of movements P08-12
3:(waiting time P08-11-> reverse rotation movement P08-07)*
number of movements P08-12->(waiting time P08-11-> forward
rotation movement P08-07)* number of movements P08-12
4:(waiting time P08-11-> forward movement P08-07-> waiting time
P08-11-> reverse movement P08-07)* number of movements P08-12
5:(waiting time P08-11-> reverse movement P08-07-> waiting time
P08-11-> forward movement P08-07)* number of movements
P08-12
Setting range: 1-2000, unit: 0.1 turn
Number of turns per step when setting program JOG
Setting range: 1-10000, unit: rpm
Set the maximum speed of movement when program JOG is
running
Setting range: 2-10000, unit: ms
Set the acceleration and deceleration time during program
JOG operation
Setting range: 0-10000, unit: ms
Set program JOG run wait time
Setting range: 0-10000, unit: Time
Set the number of program JOG moves
Setting range:0-1
0: Self-timing, inertia identification
143