The larger the measurement range, the better the tracking accuracy and
stability.
[Start]: Start calibration.
[Clear]: Clear the calibration parameters.
Automatic setting: automatic setting is the process of adaptive adjustment
of the height controller motion control system parameters, and then get the best
active gain level based on the existing machinery, the user can also manually modify
the parameter.
Following gain level: Following gain level can be adjusted to follow the
following speed, the higher the level, the faster the following speed, but in some
cases may appear vibration instability. Parameter range 1-30, default value is
11, can be obtained by automatic setting or manually modified.
[Start]: Start setting.
9.4 Diagnose
Under the diagnose interface, you can view the working status of the height
controller, the input and output port status and other information. It can diagnose
the working state of the elevation and troubleshoot.
Figure 9.4 Laser height-modulator diagnosis
Jog test
Current coordinates: Current coordinate position of the elevator.
Current speed: the speed at which the height regulator is currently running.
110
    "