7. 2 Global Parameters
Global parameters: cutting speed, manual moving speed, empty move speed setting, kerf
value, cutting type selection, system mode parameters, etc.
Figure 7. 3 Global Parameter interface
Figure 7.1 common parameter of the system.
The parameter
unit
name
scope
Parameter remarks
Manual low speed mm/min
The low speed of moving the torch
Manual mid speed mm/min
The mid speed of moving the torch
Manual high speed mm/min
G00 move speed
mm/min
The high speed of moving the torch
The speed at which the cut torch
moves when performing G00 or quick
return. When moving empty, the
torch will move only, not cutting.
Forward / backward mm/min
speed
Speed when forward or backward
along the path during a pause in
the cutting.
Blowing gas pressure BAR
The outlet pressure of the air valve
is controlled by DA, and the air
pressure is linear with DA.
Open gas delay
s
Time to open the air before the light
opens
110
    "