Follow error delay ms
Local capacitor
change alarm value
Enable real-time
calibration
Enable active
anti-collision
Enable the non-metal
calibration
Enable vibration
suppression
0-6000
0-9999
delay of the following error, the
better the inhibition of the
capacitance mutation.
If the difference between the
current height and the following
height in the following state is
greater than the following error
alarm, and the duration is greater
than the following error delay,
the following error alarm will be
triggered. The possible reasons:
the torch moves out the plate, the
plate jitter abnormally, etc.
that caused sudden change of
capacitance. The greater the
delay of the following error, the
better the inhibition of the
capacitance mutation.
It is recommended to set to 10% to
20% of the valid value in the
floating head calibration result
After the real-time calibration
is enabled, the regulator will
fine-tune the calibration curve
according to the body capacitance
change to compensate for the
influence of the cutting head by
the environment or the cutting
temperature rise, thus reducing
the number of manual calibration
of the regulator.
Predict whether the cutting head
will touch the plate before
following and lift it before the
collision.
Floating head calibration function
of non-metal sheet metal or
non-metal workbench.
When cutting a thin plate surface,
110