Table 9.1
The parameter name
unit
Parking coordinates mm
Z axis stroke
mm
Follow method
Empty move speed mm/s
Acceleration
G
Jog move low speed mm/s
Jog move high speed mm/s
scope
Parameter remarks
The stopping coordinate after
zero or closing, which is also the
target position of the cutting
head after finish cutting. The
value does not exceed the Z axis
stroke, and try not to be too close
to the plate surface
The maximum distance that the Z
axis can be moved down from the
mechanical origin.
Follow mode when the regulator
control mode is IO mode:
Follow directly
Progressive
follow
perforation
The speed at which the head
moves up and down in the
non-cut state. Not greater
than (screw pitch * max speed/
60). Unit mm/s. In order to
improve
the
operation
efficiency and stability of
the elevator, it is
recommended to set the speed
around the servo motor rated
speed.
Acceleration during the cutting
head movement
Not greater than (screw pitch *
upper speed / 60). Must be less
than the jog moving high speed.
Not greater than (screw pitch *
upper speed / 60), must be
greater than the jog moving low
speed.
110
    "