Specialized Concentrated Focused
Attached List: the relationship among parameters Pr008, Pr009 and Pr010.
Pr008 Pr009
1~220
_
(no
influence)
0
0
1~230
Pr010
_
(no
influence)
1~230
1~230
Command
Pulse Input
Description
Encoder Resolution
[Setting Value of Pr008]
Position
Command
As shown above, the process is undergone in terms of the
setting value of Pr008, not affected by the settings of Pr009
and Pr010.
Command
Pulse Input
Encoder Resolution
Position
Command
[Setting Value of Pr010]
When the values of Pr008 and Pr009 are both set to “0”, as
shown above, the process is undergone in terms of the
setting value of Pr010.
Command
Pulse Input
[Setting Value of Pr009]
Position
Command
[Setting Value of Pr010]
When the value of Pr008 is “0”, but the value of Pr009 is not
“0”, as shown above, the process is undergone in terms of
the setting values of Pr009 and Pr010.
84Driver
    "