Hikrobot Machine Vision Software User Manual
signals (i.e.,contact bouncing signals). Once you set a debouncer time, signals that
do not last longer than the time will be ignored.
Strobe
Used the selected line to output signals to control light source of the camera.
Line Source
Exposure Start Active
If the exposure starts, the output signals for controlling the light will be triggered.
Acquisition Start Active
If acquisition starts, the output signal for controlling the light will be triggered.
Acquisition Stop Active
If acquisition stops, the output signal for controlling the light will be triggered.
Frame Burst Start Active
If the burst of a frame starts, the output signal for controlling the light will be
triggered.
Frame Burst Stop Active
If the burst of a frame stops, the output signal for controlling the light will be
triggered.
Soft Trigger Active
Trigger the output signal for controlling the light via the Software.
Hard Trigger Active
Trigger the output signal for controlling the light via the camera.
Counter Active
Trigger the output signal for controlling the light by the counter.
Timer Active
Trigger the output signal for controlling the light by the timer.
Strobe Enable
Enable the strobe mode.
Strobe Line Duration
Set the time duration (unit: μs) of the output signal for controlling the light.
Strobe Line Delay
Set the delay time (unit: μs) for triggering the output signal for controlling the light if
the events defined in Line Source occur.
Strobe Line Pre Delay
Set the pre delay time (unit: μs) for triggering the output signal for controlling the
light if the events defined in Line Source occur.
64