Hikrobot Machine Vision Software User Manual
6.12.2 Configure Temperature Screening Parameters
Besides drawing temperature screening regions, you can also set parameters related to
screening, alarm, and display on the Temperature Screening Region Settings window.
Note
For the configurations to take effect, you can either click OK on the bottom right corner of
the window or click Apply Param on the bottom left. Clicking OK will close the
configuration window, whereas clicking Apply Param will not and you can continue with
the configurations.
Screening
Under Screening, you can configure parameters related to the palette mode, camera basics,
global screening, and expert mode.
Palette Mode
Select a palette mode for the camera from White Hot, Black Hot, etc.
Camera Parameter
Brightness
Adjust the brightness level of the live view image correspondingly. The larger the
value, the brighter the image.
Gamma Enable
When enabled, you can set the gamma value correspondingly. The larger the value,
the stronger the contrast.
Sharpness Enable
When enabled, you can set the sharpness level for the edges of the live view image.
Noise Reduction Enable
When enabled, the signal-to-noise ratio of the image will be boosted, so as to improve
the quality of the image.
Global Screening
Set the global temperature screening parameters for the temperature screening regions.
Atmospheric Transmissivity
If a germanium glass needs to be added in front of the lens of the infrared camera, the
transmittance of the germanium glass can be set by this parameter.
Note
If no germanium glass is needed, you can keep this parameter as 100.
Temp Measurement Range
Select a temperature measurement range as needed from -20℃ ~ 150℃ and 0℃ ~
106