Hikrobot Machine Vision Software User Manual
Rising Edge
Specify that the trigger is considered valid on the rising edge of the source signal.
Falling Edge
Specify that the trigger is considered valid on the falling edge of the source signal.
Level High
Specify that the trigger is considered valid if the level of the source signal is high.
Level Low
Specify that the trigger is considered valid if the level of the source signal is low.
Trigger Delay
Specify the delay in microseconds (μs) to apply after the trigger reception before
activating it.
Auto Trigger Time
Specify the interval in milliseconds (ms) to generate the trigger signal automatically.
Note
Auto Trigger Time is only available when you set Software as the Trigger Source.
Auto Trigger Time is only effective when the Enable Auto Trigger switch is set to on.
Enable Auto Trigger
Enable the software to generate the trigger signal automatically.
Note
The parameter is only available when you set Software as the Trigger Source.
Trigger Software
Click Execute to execute the TriggerSoftware command so as to generate the trigger
signal.
PostDivider
Sets the PostDivider value for the PostDivider sub-module.
PreDivider
Sets the pre-divider value for the pre-divider sub-module.
Encoder Selector
Selects which Encoder to configure.
Encoder Source A/B
Selects the input line as signal source for the shaft encoder module.
Encoder Trigger Mode
This enumeration value selects the circumstances for the shaft encoder module to
62
    "