64
2) Machine config tool ->Return Org-> Select ”Enable”
3) Machine config tool ->Alarms-> Input the value of “Max Dev tolerance of the gantry sync”.
When the beam is subject to severe collision or serious distortion, which makes the deviation exceed
this value, we need to re-examine the machine. You can change this value according to the actual
situation of the machine.
6.2.2 Gantry initialization and synchronization
To prevent the error of gantry synchronism, please confirm the following situations before
initialization:
1. The beam of machine has been corrected.
2. The machine can correctly move and the direction is right.