59 CypCut Laser Cutting Control System
Motion axis shows each axis signal and the corresponding encoder feedback value; Pulse test is
used to send fixed pulse to single axis, in order to test the accuracy of pulse equivalent; Limit signal is
used for displaying whether the cutting head is hit limit; PWM is used to show the situation of laser
switch; The valid situation of 12 inputs and 18 outputs are also shown.
5.7 BCS100
This function must be used compatible with our height controller BCS100. By clicking "
",
you can operate a series of actions in the software, such as Return to origin, Follow to, Absolute
positioning and one key calibration, to control BCS100. And you can also operate via BCS100
monitoring interface without operating on the entity, which is more convenient and quick.
5.8 QCW
QCW is a mode of laser operation. CW and QCW is two modes d of laser. CW is continuous
light, and QCW is pulse laser. By clicking "
parameters.
" button, you can set the appropriate optical