CypCut Laser Cutting Control System
52
Some parameters of tab “Global Parameters” are list in the table below.
Motion Parameters
Move Speed
Speed during move (not the speed during processing).
Move Acceleration
The maximum acceleration of each shaft during move. It needs to be
used with move speed.
Frame Speed
Speed of framing.
Cut Acceleration
The maximum acceleration of each shaft during track processing. It
needs to be used with cut speed.
PWM Frequency
Default Current
Default Pressure
Gas Delay
Initial gas delay
Switch gas delay
Cooling point delay
Maximum
height
follow
Using frog style Lift
Enable follow in dry cut
Disable follow
No alarm during
piercing
Unlift when move
distance less than
Unit Selection
Laser Parameters
PWM frequency is used when laser on.
Peak current is used when laser on.
Air pressure used in manual mode
Delay time used in step “Gas Delay” of PLC during piercing
Additional delay time on the basis of gas delay when puff after
processing
During replacing the gas, Delay time that is used to discharge all
existed gas and enter new gas .
Puff time during cooling.
Follower Parameters
Each type of cutting head has a upper limit height to follow. When
you need to follow the height above this maximum height due to
demand, such as piercing, the height controller will follow through
two steps, that is, firstly follow to the position near the plate surface,
and then lift up. This parameter is used to set the height of the upper
limit for following.
After Z-coordinate lifts to the specified height, X-coordinate and
Y-coordinate begin move, so as to shorten the time of move.
The default Z-axis can’t move in the default case of “dry cut”. If users
want to follow during “dry cut”, the user can select this option.
Following and cutting is needed during normal processing. If you do
not need to follow during the processing, you can select this option.
Under the environment, such as cutting thick plates, large quantities
of spark generated during piercing could cause alarm of height
controller, thereby interrupting the process. If you select this option,
you can ignore the alarm of capacitance class generated by height
controller during piercing. Of course, ignoring the alarm will also
bring some risks.
If you select “Short Move unlift”, when move length is less than this
length, the height controller will not lift during moving and keep
following.
You can make a selection according to your use habits.