3.5 Cutting Parameter
Nozzle height
Cutting Parameter
Set the cutting height from the nozzle to the plate.
Speed
Set the command speed of cutting.
Power
Set the peak power of the laser in cutting.
Cut freq
Set the frequency of the laser in cutting. It refers to the time of beam out in 1 second. The
higher the value, the more continuous the laser beam is. 5000Hz is a successive beam.
Duty cycle
Set the duty cycle of the laser in cutting. It refers to the ratio of beam-out duration in one
beam-out cycle and the total time. The higher the ratio value, the higher the average power is
when beam out. When it is 100%, it means the average power equals the peak power.
Gas pressure
Set the assist gas pressure in cutting.
Gas type
Set the assist gas type. There are the air, oxygen, and nitrogen.
Laser-on delay
Set the delay at the start point of graphic processing to make cutting effect better.
3.6 Other Parameters
Slow start
Length
Speed
Other Parameters
Select to use the slow start function.
The range of distance at which the slow start takes effect, starting from the start of the
contour and including the leadline. Use to avoid not penetrating in cutting thick plates.
Set the slow start speed.
Slow stop
Select to use the slow stop function.
Length
Set the distance from slow stop starting to the end of cutting path.
Speed
Set the cutting speed when using slow stop function.
Duty
Set the duty cycle of laser beam out when slow stopping.
Pulse freq
Set the laser frequency when slow stopping.
Beam off early
The distance to turn the beam off in advance before reaching the end of cutting path.
Control mode
Set the control mode of slow stop.
V1.0
Raytools AG © Copyright
53 |87