Friendess CypCut Laser Cutting Control System
93 / 103
2. Open CypCut-Diagnosis-Card monitor check the encoder feedback that must be
same with command pulses.
3. Plate dimension setting should be same with the real dimension.
4. The inclination angle of the steel plate should not exceed 10 degrees.
5. Before start find edge, it should set reference point as top left, top right, bottom
left or bottom right, otherwise it's not available for find edge function. Reference
point defines the direction that laser head starts to find plate edge.
6. You have to locate laser head within the plate before start find edge function.
7. You have to make sure laser head can properly follow to the plate.
6.4 Infrared Find Edge
CypCut V6.3.642.6 and above support find edge by photoelectric sensor.The
photoelectric sensor support Omron E3Z-L61.
6.4.1 Photoelectric Switch
The effective working range of the photoelectric switch is 90 +30 mm.
Installation thread is M3; the switch can switch into 2 modes. Switch to L lights on
when outputs signal, and switch to D lights off when outputs signal. Spin button can
adjust the sensitivity of the switch.