Friendess CypCut Laser Cutting Control System
79 / 103
You can set the following parameters ‘Y deviation’ is the horizontal distance
between sensor switch and laser beam accessed by program automatically; ‘Brace bar
thickness' (tooth thickness) reduce the machine tooth effect to the sensor; ‘Seek height' used
under scenario that sensor switch mounted on the laser head. Users can jog Z axis up
or down to adjust the sensor position and set as 'seek height’. Each time start find
edge it will locate to this position.
Notice: The inclination angle of the steel plate should not exceed 40 degrees.
5.2.3 Cut Off (open in platform configuration tool)
Open this function it will show options under ‘Seek edge’ drop down menu. This
function used to split plate.
Cut off safe distance: Laser head starts from
outside plate in a fixed height after pass this distance
will follow to plate.
X cut off (left to right): Select this option when
execute split-plate function, laser head will follow
out of the plate then cut in from left side, then follow
out of the plate cut in from right side.
Notice: When split plate it should use parameter
of green layer.
    "