Interfacing a frame scan camera 51
6. Make sure the settings for the horizontal synchronization and the vertical
synchronization are set to active. Unless the frame grabber is set as the master,
synchronization signals will come from the camera, and the default value for the
synchronizations signals is not enabled. You enable these options in the Digital
Synchro. tab.
PRE9LIMMAINYA2R0Y05 If the digitizer is selected as the synchronization signal source, you should enable
the output synchronization signals on the Digital Synchro. tab. If the camera is
1selected as the synchronization signal source, you should enable the input
synchronization signals on the Digital Synchro. tab. By default the camera is
selected as the synchronization signal source.
7. Adjust the other DCF settings according to the specifications for the camera.
8. Save the DCF using the Save As command.