FSCUT2000C laser cutting control system User Manual
60
6.5 Laser not emitting light
1. Check whether the laser setting is correct or not
Determine correct laser configuration in the platform configuration tool (YLS
series of IPG has difference between German version and American version)
Determine whether serial port or Ethernet communications is applied and
communications port is configured correctly.
Determine whether the DA signal control is applied to control the peak power,
DA is selected correctly.
PWM-enabled and light-enabled is configured correctly.
2. Check the output signal of PWM and DA
Modify the output value of DA and PWM in the interrogation window of
CypCut software (fileinterrogation window). Use multi-meter to test whether
DA of BCL3762 terminal block and voltage of PWM output port is normal or
not.
If PWM output voltage is too low or the DA signal has no output, try to
replace another interface of PWM or DA.
If it’s hardware failure, please contact our technical support or apply for
repair.
3. Check connection
Check the connection of PWM, serial cable and laser control signal lines.
Make sure serial cable use a shielded cable. 2 pin and 3 pin need to be cross.
4. Check laser
Use the matching software coming with laser to do self-checking and to check
light change, and to judge whether laser is working normally.
In the case of serial communication, not allow to open multiple software to
communicate with lasers at one moment.
In the case of no serial port communication, you can click debug mode to view
the sent instructions and the response of the laser.
6.6 Scan cutting setting instructions
6.6.1 Function brief introduction
CypCut6.3.495 later version adds new functions: Scan cutting, also called fly
cutting. Scan cutting of regular array pattern (suit for sheet metal) and naturally
successive cutting of arc can be achieved by this function, thus greatly enhancing the
processing efficiency. Function buttons are shown in the area of the following figure.
    "