45 FSCUT2000C laser cutting control system User Manual
Follow: open the input port for following.
Retract: set output port for raising (close following).
Stop/ Hold: Set output port for stopping Z axis motion.
Jog up: Set output port for manually controlling Z axis raising.
Jog down: Set output port for manually controlling Z axis declining.
Tracking in place signal: Set input port for collecting and following signal.
Tracking in place signal level: Set effective mode for controlling signal level.
Notes: If port is set as “0”, it means it is not available. If there is no this signal,
please don’t set randomly, otherwise it may cause logical error!
3.8 Auxiliary gas configuration
Valve:Set the total output port for auxiliary gas correspond to switch.
High pressure valve and low pressure valve: Set the output port for high
pressure gas and low pressure gas.
Air Port: Set output port for air selection.
O2 Port: Set output port for oxygen selection.
N2 Port: Set output port for nitrogen selection.
DA Pressure:Users can select two interfaces of analog of 1604 card to regulate
auxiliary gas pressure
Alarm detecting: Choose input port for gas alarm.