FSCUT2000C laser cutting control system User Manual
24
Basic setting parameters of Mi Mitsubishi MR-J3 - A series
Parameter
Type
Recommended
value
Implication
PA01
0
Control mode-Position mode
PA13
0011
Negative logic: Pulse+Direction
Note:
Parameter settings above can guarantee basic sports only under the circumstances
of the right wiring connection, not ensure control precision. And if you need to further
optimize campaign results, please adjust the rigidity, gain, inertia ratio and other
parameters.
2.3.4 Origin and limit input
X-: the limit of minus X direction, dedicated input signal and low level is active;
X0: the origin signal, dedicated input signal and low level is active;
X+: the limit of positive X direction, dedicated input signal and low
level is active;
COM: GND, the general interface of the above three signals;
Y-: the limit of minus Y direction, dedicated input signal and low level is active;
Y0: the origin signal, dedicated input signal and low level is active;
Y+: the limit of positive Y direction, dedicated input signal and low
level is active;
COM: GND, the general interface of the above three signals;
W-: the limit of minus W direction, dedicated input signal and low level is active; W0:
the origin signal, dedicated input signal and low level is active;
W+: the limit of positive W direction, dedicated input signal and low level is
active;
COM: GND, the general interface of the above three signals;
The input logic of limit and origin signal can be modified through “platform
configuration tool” coming with the CypCut software. Please refer to chapter 3 platform
configuration tool for more details.
2.3.5 General input
There are 15 general inputs with IN1~IN15. 15 general inputs can be configured as
various custom buttons or alarm input through “platform configuration tool” coming
with the CypCut software. Please refer to chapter 3 platform configuration tool for
more details.
2.3.6 General output
There are 8 relay outputs with OUT1~OUT8. 8 relay outputs can be configured as
the control port corresponding to “laser”, “auxiliary gas”, “height controller”, “indicator
light” through “platform configuration tool” coming with the CypCut software. Please
refer to chapter 3 platform configuration tool for more details.
    "