39 FSCUT2000C laser cutting control system User Manual
3.4 Mechanism configuration
Select drive mode for Y axis (single drive or double drive), based on
mechanical structure, and then configure information of rotation axis.
X axis range: Width of rectangle on CypCut painting interface. After start
software limit protection, max motion range for X axis.
Y axis range: Height of rectangle on CypCut painting interface. After start
software limit protection, max motion range for Y axis.
Pulse equivalent: Pulse count sent for 1 mm motion. Count automatically by
actual motion distance and pulse count, and millimeter value can be set as four
digits after the decimal point. Pulse equivalent= pulse count/ millimeter value.
Servo alarm: Select servo alarm signal logic, or close servo alarm
feedback. Speed limit: limit max speed and acceleration for CypCut
software.
Pitch Compensation: Error compensation for Interferometer data.
Verticality correction: When installation of X axis and Y axis is not 90o, the
deviation can be eliminated through “Verticality correction”
    "