FSCUT2000C laser cutting control system User Manual
12
Typical connection of optoelectronic switch is shown as below, which must use 24V
switch of the NPN type (low level is active)
BCL3766
COM
optoelectronic switch
Y-
OUT
C
24V
+
Typical connection of contact switch is shown as below:
BCL3766
contact switch
COM
COM
Y+
NO
Typical connection of magnetic switch is shown as below, which must use 24V
switch of the NPN type.
BCL3766
COM
magnetic switch
0V
IN6
OUT
24V
V+
    "