FSCUT2000C laser cutting control system User Manual
18
Basic setting parameters of Panasonic A5 series
Parameter type Recommender value Implication
Pr001
0
Control mode must be set as location mode.
Pr007
3
Have to select “Pulse+Direction” mode
Pr005
1
When using high-speed pulse connection
mode, this parameter is set as 1, and the
maximum supported pulse frequency is
3Mpps; When using low-speed pulse
connection mode, this parameter is set as 0,
and the maximum supported pulse
frequency is 500Kpps;
The wiring diagram of Yaskawa servo
Fscut-DB15
Yaskawa-Σ-50Pin
Signal pin
PUL+ 1
PUL- 9
DIR+ 2
DIR- 10
Shielding layer
pin signal
7 PULS
8 *PULS
11 SIGN
12 *SIGN
A+ 3
A- 11
B+ 4
B- 12
Z+ 5
Z- 13
33 PAO
34 *PAO
35 PBO
36 *PBO
19 PCO
20 *PCO
24V 8
SON 6
CLR 7
ALM 14
0V 15
47 +24V IN
40 /S-ON
44 /ALM-RST
31 ALM+
1 SG
32 ALM-
Basic setting parameters of Yaskawa Σ series
Parameter type
Pn000
Pn00B
Recommender value
001X
None
Pn200
2000H
Implication
Control mode must be set as location mode.
When the input is single-phase power,
modify into 0100
When the pulse frequency is lower than
1Mpps, please select 0000H mode;
When the pulse frequency is up to1Mpps -
4Mpps, please select 2000H mode.
Pn50A
Pn50B
8100
6548
Can be driven in co-rotation side
Can be driven in reverse side
    "