FSCUT2000C laser cutting control system User Manual
44
3.7 Height controller configuration
3.7.1 Use BCS100 network height controller
If use network height controller matched by our company (Abbreviation as
BCS100), please set IP address which should be s the same as the network address in
the BCS 100 parameters.
IP address setting, please refer to instructions P2.5.6 of BCS100 for more detail.
3.7.2 Not use BCS100 network height controller
CypCut also supports input/output port to control height controller of other
brands. Users can set the output port of following, rise (close following), stop
(Hold), move up and down by clicking, and input port of following signal, by
themselves.